Description
32 Amp RCBO is suitable for circuits with rated voltage 230V AC, frequency 50/60Hz, and rated current below 32Amp.
Its working principle is that 32 Amp RCBO provides indirect protection to the operator’s body when exposed live parts should be connected to an appropriate ground electrode.
In addition, RCBO also provides overcurrent protection for circuits in homes, businesses, and other similar devices. At the same time, it can also prevent the potential fire hazard caused by the ground-fault current when the overcurrent protection device fails.
32 Amp RCBO Special Note
1. RCBO cannot prevent electric shock caused by direct contact between two protected lines or leakage current between the two lines.
2. RCBO is designed for home installation and other similar applications, non-professional operation, and no maintenance.
3. RCBO with a rated sensitivity of 100mA can be used as an auxiliary protective device to prevent other protective devices from being unable to prevent electric shock.
4. It is recommended to install special devices on the upstream line of RCBO, such as surge protectors, lightning arresters, etc., to prevent potential surge voltage and current from appearing on the power input side.
5. The RCBO overcurrent protection value is fixed and no further adjustments are made.
Model Name | TOBN1-32 |
Model | Electronic type |
Residual Current characteristic: | AC |
Pole No: | 1P+N |
Tripping Curve | C |
Rated current(A) | 6-32 |
Rated voltage | 240V |
Rated frequency | 50/60Hz |
Rated residual operating current |△(A): | 0.03 |
Rated residual non operating current |△ no: | 0.5|△ n |
Rated conditional short-circuit current inc: | 6kA |
Rated conditional residual short-circuit current |△c: | 6kA |
Tripping duration: | Instantaneous tripping ≤0.1s |
Residual tripping current range: | 0.5||△n~|△n |
Electro-mechanical endurance | ≥4000 cycles |
Connection capacity: | RIGID CONDUCTOR 16MM² |
Connection terminal | Screw terminal Pillar terminal with clamp |
Fastening torque | 2.0 Nm |
Installation | On symmetrical DIN rail 35mm Panel mounting |
1P+N | AC | Width in 9 -mm modules | ||||
B Curve | Voltage Rating(In) | Sensitivity(Len) | 10mA | 30mA | 100mA | 2 |
230V 240V | Rating(In) | 6A | TOBN1-32/1N/B6/001 | TOBN1-32/1N/B6/003 | – | |
10A | TOBN1-32/1N/B10/001 | TOBN1-32/1N/B10/003 | ||||
16A | TOBN1-32/1N/B16/001 | TOBN1-32/1N/B16/003 | ||||
20A | TOBN1-32/1N/B20/001 | TOBN1-32/1N/B20/003 | ||||
25A | TOBN1-32/1N/B25/001 | TOBN1-32/1N/B25/003 | ||||
32A | TOBN1-32/1N/B32/001 | TOBN1-32/1N/B32/003 | ||||
C Curve | Voltage Rating(In) | Sensitivity(Len) | 10mA | 30mA | 100mA | |
110V | Rating(In) | 10A | – | TOBN1-32/1N/C10/003 | – | 2 |
16A | TOBN1-32/1N/C16/003 | |||||
20A | TOBN1-32/1N/C20/003 | |||||
25A | TOBN1-32/1N/C25/003 | |||||
32A | TOBN1-32/1N/C32/003 | |||||
230V 240V | Rating(In) | 6A | TOBN1-32/1N/C6/001 | TOBN1-32/1N/C6/003 | TOBN1-32/1N/C6/01 | |
10A | TOBN1-32/1N/C10/001 | TOBN1-32/1N/C10/003 | TOBN1-32/1N/C10/01 | |||
16A | TOBN1-32/1N/C16/001 | TOBN1-32/1N/C16/003 | TOBN1-32/1N/C16/01 | |||
20A | TOBN1-32/1N/C20/001 | TOBN1-32/1N/C20/003 | TOBN1-32/1N/C20/01 | |||
25A | TOBN1-32/1N/C25/001 | TOBN1-32/1N/C25/003 | TOBN1-32/1N/C25/01 | |||
32A | TOBN1-32/1N/C32/001 | TOBN1-32/1N/C32/003 | TOBN1-32/1N/C32/01 |